Complex Métro Longueuil (“CML” and / or the “Complex”) is located adjacent to the Montréal South Shore’s principal transportation hub on de Serigny Street and Lafayette Boulevard in the City of Longueuil. The Properties are connected to Longueuil Metro station and bus terminal (Intercar Terminus Longueuil) which form the major centre for public transit serving the South Shore.

LEASING INQUIRIES

Fil Iapalucci fiapalucci@redbourne.ca

Telephone: (514) 940-1555 Ext:233   Fax: (514) 940-1549

Redbourne 1555 Peel Street, Suite 700, Montreal (Quebec) H3A 3L8 Canada

AVAILABILITIES
Suite Floor Area
(sq.ft.)
Contiguous
Area(sq.ft.)
Availability
(mm/yy)
FLOOR
PLAN
SUITE
PLAN
400 4 13,463 N/A Immediate N/A
210 2 6,997 N/A Immediate N/A
BUILDING SPECIFICATIONS
Built:1976
Floors:6
Parking:80 spaces / total of all 3 buildings: 314 spaces
Windows:Fixed double-pane thermal glazing units with metal frames
Structure:Foundation Cast-in-place concrete foundation walls. Reinforced concrete columns and beams. Reinforced concrete floor decks. The first parking level, located on the ground floor level, extends further than the south limit of the building.
Elevators:Two (2) Armor cable-driven elevators with a capacity of 1130 kg. Interior cabins recently renovated (2015). Modernization to be completed in 2016.
Air Conditioning: Sanyo packaged terminal A/C units and duct heaters in the plenums on each floor. Electric baseboard heaters (supplying supplementary heating). Six (6) Reznor suspended heaters (located in the parking garage levels).
Heating: Electrical coils heaters are installed in the duct system Electric baseboard heaters (supplying supplementary heating) Four (4) Reznor suspended heaters (located in the parking garage levels.
Air Exhaust: Two (2) Twin City exhaust fans (garage levels). One (1) Air Care unit with heat recovery wheel system. Two (2) Air Care exhaust fans. * Vulcain electrical ventilation system, CO detectors and exhaust fan system (interior parking).
Electric Supply:One (1) Federal Pioneer main panel rated to provide 1200A/347/600V.
Emergency Power:One (1) Kohler Power System diesel powered generator with a 80-kw capacity equipped with a diesel 1000-L above storage tank.
Lighting:Fluorescent and halogen lightin
Security:Proximity card access system. 24/7 agent.
Sprinklers: The building is fully protected with a dry and wet sprinkler systems which includes standpipes installed on the parking garage level of the building Siamese connections are located near the north-west corner of the building.
Fire Detectors:The alarm system includes smoke and heat detectors, alarm bells, pull stations and a fire alarm panel.